What Is DN in Piping Systems and Valves?

DN (Diameter Nominal) is a standardized nominal size designation used for components of piping systems. DN is commonly used for pipes, valves, flanges, fittings and other pipeline components.

According to DSTU EN ISO 6708:2022, the DN designation consists of the letters DN followed by a dimensionless whole number that is indirectly related to the physical size of the bore or the outside diameter of the end connections. Therefore, DN should not automatically be interpreted as an exact diameter measured in millimetres.

What Does DN Mean?

Examples include:

  • DN 15;
  • DN 25;
  • DN 50;
  • DN 100;
  • DN 200;
  • DN 500.

The DN designation provides a standardized way of identifying the nominal size of piping components and helps engineers select compatible products.

In industrial piping systems, DN is one of the key parameters used when selecting valves, flanges, fittings and other components.

Is DN the Actual Inside Diameter?

No. One of the most common misconceptions is that DN 100 means that the actual internal diameter of a pipe is exactly 100 mm.

ISO 6708 defines DN as a nominal, dimensionless designation. The number is indirectly related to the physical dimensions of the piping component and should not be treated as a direct measurement unless the applicable standard specifically defines such a relationship.

The actual inside and outside diameters depend on the pipe standard, material, wall thickness and design.

Why Is DN Important?

DN is used to:

  • select the correct pipeline valve size;
  • choose compatible flanges;
  • match pipes and fittings;
  • identify valve and fitting sizes;
  • prepare equipment specifications;
  • check component compatibility;
  • design and maintain piping systems.

For example, a DN 100 valve must be selected with the appropriate connection dimensions and other technical parameters for the particular piping system.

Standard DN Sizes

ISO 6708 provides a series of preferred nominal sizes, including DN 10, DN 15, DN 20, DN 25, DN 32, DN 40, DN 50, DN 65, DN 80, DN 100, DN 125, DN 150, DN 200, DN 250, DN 300 and larger sizes.

Steel pipes of different diameters stacked on a warehouse rack

Industrial piping systems may use both small sizes, such as DN 15–DN 50, and large sizes such as DN 300, DN 500, DN 800 or DN 1000 and above.

DN, ID and OD

Three terms should be distinguished:

DN — nominal size.

ID (Inside Diameter) — actual inside diameter.

OD (Outside Diameter) — actual outside diameter.

A given DN does not necessarily mean that all pipes with that designation have exactly the same internal diameter. Actual dimensions depend on the applicable manufacturing standard and wall thickness.

DN in Pipeline Valves

DN is widely used to identify industrial pipeline valves and components, for example:

However, DN alone is not sufficient to select a valve. Other important parameters include PN, connection type, body material, operating pressure, temperature, medium and valve design.

DN vs PN

DN identifies the nominal size of a piping component.

PN is used to designate a nominal pressure parameter according to the applicable standards.

For example, DN 100 PN 16 contains two different characteristics: DN 100 indicates the nominal size, while PN 16 indicates the nominal pressure designation.

How to Select a Valve by DN

First, determine the nominal size of the existing or planned pipeline. Then check the required PN, connection standard, flange or thread dimensions, material, operating medium, temperature and other technical requirements.

When replacing existing equipment, it is especially important to verify the manufacturer's dimensional drawings and technical documentation because the same DN designation does not necessarily mean that every mounting dimension is identical.

Conclusion

DN is a standardized nominal size designation for piping system components. It is used to identify and match pipes, valves, flanges and fittings.

DN should not automatically be treated as the exact inside or outside diameter in millimetres. Correct component selection requires consideration of the applicable standard and the complete technical specification of the product.

FAQ: What Is DN?

What does DN mean in piping?

DN means nominal size and is used to identify the size of piping system components such as pipes, valves, flanges and fittings.

Is DN the inside diameter of a pipe?

No. DN is a nominal designation and is not necessarily equal to the actual inside diameter.

What does DN 50 mean?

DN 50 identifies a nominal piping component size. The actual dimensions depend on the applicable standard and product design.

What does DN 100 mean?

DN 100 is a nominal size designation for a piping component. The exact inside, outside and connection dimensions must be checked against the relevant standard and manufacturer's documentation.

What is the difference between DN and PN?

DN refers to nominal size, while PN refers to the nominal pressure designation. They describe different characteristics of a piping component.

How do I select a valve by DN?

Determine the required DN and then verify PN, connection type, material, operating medium, temperature and other technical parameters.

Do all manufacturers use the same DN sizes?

The DN designation is standardized, but actual construction and connection dimensions must be checked against the applicable standard and manufacturer's technical documentation.