Quantity
|
Total
|
||
|
|
|||
KAN-therm Steel pipe
KAN-therm Steel pipe is a thin-wall carbon-steel press pipe with an external zinc coating for closed building services. Joints are made by pressing a fitting, without welding or threading, so a riser or floor circuit goes in faster. It is specified for heating, chilled water and process heat. A wrong diameter, wall thickness or seal type shows up at commissioning, when the joint will not hold the design duty.
Main types of KAN-therm Steel pipe
This group is supplied as 6 m bars. They are split by outside diameter and wall thickness, not by joint method: pressing is the only connection. Sizes 12–18 mm with a 1.2 mm wall cover appliance tails and short runs at a manifold. The 22×1.5 and 28×1.5 pipes cover floor heating distribution: the bore is already useful and the bar stays manageable. Diameters 35, 42 and 54 mm with a 1.5 mm wall are used on risers and medium-flow mains. Larger pipes, 76.1×2, 88.9×2 and 108×2 mm, go into boiler rooms and substations where a large bore is needed without hot work. A tight joint needs a fitting from the same system with an O-ring.
Materials and construction
The base is low-carbon steel RSt 34-2, material number 1.0034 to DIN EN 10305-3. An external zinc layer Fe/Zn 88, about 8–15 μm, protects the surface in a dry room but does not make the pipe suitable for drinking water. For transport the bore is coated with an oil film, which must be flushed before a closed circuit is filled, following the manufacturer’s instruction. Tightness comes from a three-point M-profile press and a black EPDM O-ring. For standard EPDM the system documentation indicates about −35…135 °C, briefly up to 150 °C, and 16 bar on 12–108 mm with a standard M-profile tool. About 25 bar is only available on part of the range and only with an HP-profile tool. Solar circuits and fuel oil need a separate seal, usually Viton. Low linear expansion cuts the number of expansion devices, but conductivity is high, so exposed heating mains are insulated.
Where KAN-therm Steel pipe is used
The system is intended for internal closed circuits: heating risers and distribution, closed chilled water with condensation control, process heat, solar loops with the correct seal, fuel-oil lines and oil-free compressed air — if the duty is confirmed in the KAN-therm documentation. Open domestic hot water and potable water are not normally run in this externally galvanized pipe; sanitary circuits use other systems, including stainless press pipe. In public buildings the steel press pipe is also chosen for mechanical strength.
How to select a KAN-therm Steel pipe
Start with the medium: temperature, pressure, closed or open circuit, glycol, oil in the air. Then take outside diameter and wall thickness from the hydraulic calculation. A marking such as 28×1.5 or 54×1.5 matters more than nominal bore: the fitting and press jaws follow the outside size. The tool must match the press profile. Bar price depends on diameter, wall thickness and order volume: a project order is counted in metres plus fittings. Exact pressure and temperature limits depend on diameter, press profile and ring type — check them on the product data sheet.
Why order from Piping Systems of Ukraine
KAN-therm Steel press pipe can be ordered with matching fittings, so the joint is not mixed from different systems. Specialists check diameter, bar count and elbows against the installer specification. We supply contractors and industrial buyers in bulk and local repairs in smaller lots. Delivery across Ukraine; in Kyiv, collection or site delivery is agreed. Availability and price are confirmed before dispatch; batch documents are provided on request.
Popular sizes
- 12×1.2 mm, 6 m bar
- 15×1.2 mm, 6 m bar
- 18×1.2 mm, 6 m bar
- 22×1.5 mm, 6 m bar
- 28×1.5 mm, 6 m bar
- 35×1.5 mm, 6 m bar
- 42×1.5 mm, 6 m bar
- 54×1.5 mm, 6 m bar
- 76.1×2.0 mm, 6 m bar
- 88.9×2.0 mm, 6 m bar
- 108×2.0 mm, 6 m bar
Send a request to confirm stock and price for the KAN-therm Steel pipe diameter you need. We will check bar length and the matching press fittings for your circuit.
FAQ
Can galvanized KAN-therm Steel pipe be used for drinking water? No. It is not normally used for potable or open hot-water systems. Zinc protects only the outside, and the system is meant for closed circuits. Sanitary water needs a separate solution, typically a stainless press system.
How does the carbon-steel press pipe differ from KAN-therm Inox? Both use a press joint, but Steel is carbon steel with external zinc, while Inox is stainless steel for broader water contact. Steel fits closed heating and technical circuits where a food-grade bore is not required.
Which press profile is required? The standard joint uses an M profile and an EPDM O-ring. An HP profile is relevant only when the design relies on a higher pressure within the manufacturer’s limit for specific diameters. Jaws must match the pipe outside diameter.
Should the internal coating be flushed before start-up? Yes. For transport and storage the bore is protected by an oil film. Remove it according to the manufacturer’s instruction before filling a closed circuit, or the film can reach filters, pumps and valves.
What drives the price and how is an order counted? Price changes with diameter, wall thickness and metreage. A project order is bars of 6 m plus couplings, elbows and reducers from the same system, not the pipe alone. Current price and stock are confirmed before dispatch.