Attention! Due to the security situation, shipping delays by carriers are possible. For quick ordering and receiving invoices — please write to pipelinesystems.com.ua@gmail.com. Thank you for your understanding!
0
My order
Add products to cart
Wishlist
Add items to wish list

KAN-therm Steel flange

Sort:
View:

KAN-therm Steel flange

A KAN-therm Steel flange joins the system press pipe to a flanged valve, pump or heat exchanger without welding. One side is a press socket sized to the pipe outside diameter, the other is a flat flange for a bolted joint. The adapter is used where a closed carbon-steel heating or cooling circuit meets a flanged gate valve or ball valve. A wrong pipe diameter, gasket or bolt count cocks the joint and leaks, so the size is taken from the manufacturer’s table, not estimated on site.

Main types of KAN-therm Steel flange

The product group is the press flange, also called a KAN-therm Steel flange adapter. The socket is pressed onto the pipe with an M-profile tool: an O-ring seals the pipe, and the flange is bolted to the mating valve flange through a flat gasket. Smaller system diameters are normally taken out on a thread; the flanged transition is provided for pipes from 35 mm.

Pipe outside diameters in the manufacturer’s flange table are 35, 42, 54, 64, 66.7, 76.1, 88.9 and 108 mm. Up to 76.1 mm the table lists four bolts; 88.9 and 108 mm use eight. The flat gasket seals the flange face and does not replace the O-ring in the press zone. These are separate sealing circuits.

Materials and construction

The fitting belongs to the carbon-steel system with an external zinc coating. The zinc layer protects the outside surface in closed building services, but it is not a substitute for material selection on open aggressive water or outdoor runs. Steel grade and coating thickness are checked in the KAN-therm technical catalogue for the specific article.

The standard flange-face seal is a flat EPDM gasket. System guidance is about −35 °C to 135 °C and up to 16 bar; the catalogue allows a higher short peak for EPDM, but working limits are taken from the product data sheet. Use outside closed heating and cooling is agreed separately. Bolts, nuts and washers follow the connection table; for these flanges the reference lists M16.

Where the KAN-therm Steel flange is used

The adapter is installed in internal closed heating and cooling circuits where the pipe meets flanged equipment. Typical points are a riser isolation valve, a pump set, a heat exchanger, a boiler-room header and a metering assembly with flanged meters. On commercial and utility sites it avoids welding in the plant room and leaves a joint that can be opened for service. It is not a general fitting for process media, open circuits or potable water.

How to select a KAN-therm Steel flange

Start with the pipe outside diameter, not only the valve nominal size: 54 mm and 76.1 mm are not interchangeable even if both sit near a mid-range network size. Then match the valve flange — the manufacturer’s table rates the joint PN16 — including hole count and pitch circle. The gasket follows the same nominal size. Press with M-profile jaws or a collar for that exact diameter, then tighten the bolts in a cross pattern without cocking the face.

Price depends on pipe diameter, flange mass and whether the gasket and fasteners are included. Availability and cost of a given article are confirmed before the order; the general table does not replace the product data sheet.

Why order from Pipeline Systems of Ukraine

Pipeline Systems of Ukraine matches the KAN-therm Steel flange with the valve, gasket and fasteners so the holes and the seal line up. We work with installers, designers and industrial buyers, supply wholesale and retail, and deliver across Ukraine. On request the article can be checked against the manufacturer’s table, and documents can be issued for the specific batch.

Popular sizes

Mapping from the KAN-therm Steel flange-connection table (flat EPDM gasket, M16 bolts):

  • 35 mm — DN32, PN16, 4 bolts
  • 42 mm — DN40, PN16, 4 bolts
  • 54 mm — DN50, PN16, 4 bolts
  • 64 mm — DN65, PN16, 4 bolts
  • 66.7 mm — DN65, PN16, 4 bolts
  • 76.1 mm — DN65, PN16, 4 bolts
  • 88.9 mm — DN80, PN16, 8 bolts
  • 108 mm — DN100, PN16, 8 bolts

Ratings depend on the article and must be checked on the product data sheet. Confirm the size before ordering.

Send a request to check stock and price for the required KAN-therm Steel flange. We will match the set to the pipe and the flanged valve.

FAQ

Frequently asked questions about the KAN-therm Steel flange

How is a press flange different from a weld-neck flange? The press flange is clamped onto the KAN-therm Steel pipe with no open flame. A weld-neck flange is welded to the pipe end and is not part of the press system. On an existing Steel installation the correct part is the press version sized to the pipe outside diameter.

Can one flange fit both 66.7 mm and 76.1 mm pipe? No. Both sizes map to the same valve nominal bore in the manufacturer’s table, but the press socket is cut for one outside diameter. Jaws and collars differ as well. A swap either will not assemble or will leave an incomplete press.

Which seal goes on the flange face? A flat EPDM gasket matched to the nominal size. The O-ring inside the press socket seals the pipe and does not replace the face gasket. Another elastomer is used only when the article and the medium allow it.

Is the KAN-therm Steel flange suitable for potable water? The Steel system is intended for internal closed heating and cooling circuits. Open networks, drinking water and process media should be agreed with the manufacturer. The zinc coating is not an approval for every fluid.

What should be checked after pressing? Press with an M-profile tool for that diameter and confirm a full socket crimp. Tighten the bolts in a cross pattern so the flange face stays square. After filling, inspect both the press zone and the flat gasket: weeping at the bolts is often uneven torque, not a pipe defect.